RULES_digitize.txt -- pre-registered 2026-11-19 ~16:45 UTC, before Figures 4, 5 and 6 of Wang et al. (2026) were fetched or looked at. Page: dipole-oxygen-escape (Wang et al. 2026, ApJ 1012:79, doi:10.3847/1538-4357/aeb6ab, CC BY 4.0). Agent D. QUESTION What values do the paper's Figures 4, 5 and 6 plot, and do they agree with every number the text states? INPUTS The high-resolution JPEGs on IOP's CDN, fetched with curl -L -A "factchecked-research/1.0": https://content.cld.iop.org/journals/0004-637X/1012/1/79/revision2/apjaeb6abf4_hr.jpg (Figure 4) https://content.cld.iop.org/journals/0004-637X/1012/1/79/revision2/apjaeb6abf5_hr.jpg (Figure 5) https://content.cld.iop.org/journals/0004-637X/1012/1/79/revision2/apjaeb6abf6_hr.jpg (Figure 6) Their SHA-256 are logged in downloads/fetchlog.tsv and out/digitize_log.txt. The images stay in this working folder and are never hosted. LAYOUT NOTE (allowed after the first look, before any value is read) After the first look I may record, in RULES_digitize_layout.txt (hashed before any reading): each panel's axis ranges, the tick labels printed on each axis, whether each axis is linear or logarithmic, the marker shapes and colours, and the nominal x positions of the points. Nothing else. CALIBRATION (both readings) 1. Each axis is calibrated only from its printed tick labels: the pixel position of a labelled tick is the centre of its tick mark on the axis spine (or of the gridline, if the figure has gridlines and no tick marks). 2. Logarithmic axes map log10(value) linearly to pixels; linear axes map value linearly to pixels. 3. The calibration is a least-squares line through all labelled ticks found on that axis (at least two). Check: every labelled tick must lie within 0.5% of the axis length of the fitted line; otherwise the reading is flagged and the residuals are reported. POINT PICKING Reading A (automatic, code/digitize_a.py): marker pixels are selected by colour (markers vs. black text and axes; the thresholds are set from the layout note's marker colours and printed in the log); connected components larger than a minimum area; the point is the centroid of the component's pixels. If a marker overlaps a line of the same colour, the component is restricted to the marker's bounding box found by an erosion that removes lines thinner than half the marker's size. Ticks found automatically by scanning the spine for perpendicular dark runs. Reading B (manual, by eye, separately written code/digitize_b.py): enlarged crops of each marker and each labelled tick, with a pixel grid drawn on them, are inspected and the centre of each marker and tick is read by eye to the nearest pixel and typed into out/reading_b_pixels.json before Reading A's results are opened. The calibration is then the same least-squares rule applied to the by-eye tick positions. The two readings share no code except the image loader. AGREEMENT BETWEEN READINGS For each point, the difference A - B in log10 units (log axes) or in axis units (linear axes) is reported. The point "agrees" if |dlog10| <= 0.05 (12%); the maximum and median differences are reported. The value used afterwards is the mean of A and B (geometric mean on log axes), with half the A-B difference as the reading uncertainty, floored at 0.02 dex. CHECKS AGAINST THE TEXT (every number the text states about these figures; locators are sections/paragraphs) T1 5.76e21 s^-1 at D = 1, tilt 0 (Sec. 3 para 5; App. B) -> Fig. 4 D=1 point; Fig. 5 0 deg; Fig. 6 0 deg T2 "approximately 6e21 and 7e21" at 0 and 180 deg (Sec. 4.2 para 1) -> Fig. 5 T3 "approaching 2.0e22" at 150 deg, the maximum (Sec. 4.2 para 1) -> Fig. 5 (and that 150 deg is the maximum) T4 minimum at 0 or 180 deg (Sec. 4.2 para 1) -> Fig. 5 T5 90 deg "local decrease compared with those at 60 and 120 deg" -> Fig. 5 T6 "more than 3 times the minimum"; "a factor of ~3.5" (Sec. 4.2) -> ratio max/min in Fig. 5 T7 black circles "(0.6-2) x 10^22" (Sec. 4.3 para 2) -> Fig. 6 black circles T8 Fig. 6 black circles "same as Figure 5" (caption) -> Fig. 6 vs Fig. 5, point by point T9 "nearly 2e23" at 90 deg / 0.1D (Sec. 4.3 para 2) -> Fig. 6 blue square at 90 deg T10 "approximately 10 times higher" than 90 deg at 1D (Sec. 4.3) -> ratio blue 90 / black 90 T11 "~1e24 s^-1 in Figure 4" at D = 0.1, tilt 0 (Sec. 4.3 para 3) -> Fig. 4 D=0.1 point T12 "~10^19 s^-1 at D = 10^1" (Sec. 4.1 para 2) -> Fig. 4 D=10 point T13 "~10^25-10^26 s^-1" for D <= 1e-2 (Abstract; Sec. 4.1; Sec. 5) -> Fig. 4 D = 1e-4, 1e-3, 1e-2 T14 D=1 "~10^21-10^22 s^-1" (Sec. 4.1 para 2) -> Fig. 4 D=1 T15 D=1 -> D=0.1: "nearly 2 to 3 orders of magnitude" (Sec. 4.1; Abstract "2 to 3") -> log10 ratio T16 "spans more than 6 orders of magnitude in Figure 4" (Sec. 4.1) -> log10(max/min) over Fig. 4 T17 reversal "1 to 2 orders of magnitude relative to the present-day value" (Abstract; Sec. 5 (3)) -> log10 of Fig. 6 blue maximum / present-day value T18 "at D = 0.1 the escape rate is higher at 0 deg tilt than at 90 deg" (Sec. 4.3 para 3) -> T11 vs T9 T19 "the escape rate continues to decrease monotonically with increasing dipole moment" for D >= 1, and saturation "essentially independent of further field weakening" for D <= 1e-2 (Sec. 4.1) -> shape of Fig. 4 Classification of each stated number against the digitized value v (with its reading uncertainty u, in dex): - "m x 10^N" with one significant figure (e.g. 6e21): agrees if v lies in [(m-0.5), (m+0.5)) x 10^N widened by u. - two or more significant figures (5.76e21, 2.0e22): agrees if |log10(v/stated)| <= 0.02 + u ("approaching" 2.0e22 also accepts v up to 5% below 2.0e22 beyond that). - "~10^N": agrees if |log10 v - N| <= 0.5. A range "10^N-10^M": agrees if N - u <= log10 v <= M + u. - ratios and orders of magnitude: computed from the digitized values; agrees if the stated wording holds (e.g. "more than 3 times": ratio > 3; "a factor of ~3.5": 3.25 <= ratio < 3.75; "nearly 2 to 3 orders": 1.8 <= dex <= 3.0; "1 to 2 orders": 1 <= dex <= 2; "more than 6 orders": dex > 6; "approximately 10 times": 7.5 <= ratio < 15). - Otherwise "loose" if within a factor 1.5 (0.18 dex) of the stated number or range, else "disagrees". A "disagrees" is reported to the coordinator only after (i) both readings agree on it, (ii) the calibration check passes, and (iii) ordinary explanations are tested and written down: rounding, a sign (tailward flux negative), a different reference position, the figure plotting |flux| or a different quantity, a typo in an exponent, and whether the number might come from another figure. OUTPUTS out/fig4_points.csv, out/fig5_points.csv, out/fig6_points.csv (both readings, mean, uncertainty), out/digitize.json (checks T1-T19), out/digitize_log.txt (SHA-256 of these rules, the layout note, the images and the code), overlay images out/overlay_fig*.png (local only, not hosted). Deviations from these rules are logged as deviations.