RULES FOR THE OTHER RE-RUNS ("Our analysis"), hypomagnetic-mint Copied from each script's docstring. They were written there before that script's first run on 2026-11-04, and no hash was recorded at the time, so the order rests on our word. Lines marked as added or superseded came later; the additions made after a fresh review of the page follow that review, and RULES_review_addendum.txt says so. Each docstring is reproduced whole, including its usage line. ======== TABLES S2-S4: recheck_tables.py ======== Check Tables S2, S3 and S4 of the mint paper's supplement against themselves and against the paper. The tables are typed in below from the supplement's PDF. RULES, written 2026-11-04 after the supplement arrived and before any test was run on these tables. All of the printed tables had been seen. Student's t is the primary test, Welch's a sensitivity check, Benjamini-Hochberg at q = 0.05 and Holm at 0.05 for multiplicity. TABLES S2 AND S3 (no n printed) T1. Parse each row as GMF mean, GMF SD, NNMF mean, NNMF SD, printed P. T2. Find the n per group: for every pair (n1, n2) from 3 to 10, recompute Student's P on every row and take the pair with the smallest sum of squared log ratios to the printed P, skipping rows printed as P = 1.000. Check that against the fractional parts of the printed means, which a mean of n numbers with few decimals constrains. This is an inference from the numbers: say so if the tables don't print n. T3. Count printed P < 0.05; apply BH and Holm to the printed P values. T4. Compare the main text's quoted P values with Table S3's, row by row. TABLE S4 (note: n = 3; no P values printed, only asterisks) H1. Recompute Student's P from each mean and SD at n = 3, as the note says, and at n = 5, as the heatmap in Fig. 4A has five columns per group. H2. Report which asterisks reproduce at P < 0.05 at each n. Apply BH and Holm at n = 3. Added after a fresh review of the page, as description only (no new test): the percent changes in Table S2's raw amplitudes, for the comparison with the lab's 10-second paper. Plain Python; run with `python3 -I`. Usage: python3 -I recheck_tables.py ======== TABLE 1, THE CORRECTIONS AND THE TALLY: recheck_stats.py ======== Check the mint paper's printed statistics against its own printed means and spreads. RULES, fixed before the first run (2026-11-04): 1. Table 1 (n = 3 per group, its heading says so): for each row, Student's two-sample t on the printed means and SDs (with two groups, the paper's one-way ANOVA is the same test) and Welch's t. Compare with the printed P. A row "reproduces" if printed and recomputed P agree to within a factor of 1.5 or to within 0.03, allowing for the rounding of printed means and SDs. 2. Multiplicity: Benjamini-Hochberg at q = 0.05 and Holm at 0.05 on the printed P values, over (a) all 24 rows, (b) the 22 single compounds. Rows are not independent (one pathway; the totals contain the compounds), so this is a rough screen; BH remains valid under positive dependence. 3. The fluorescence comparisons in the Results give means, SDs and P values but no n, and a pooled sample cannot be measured on an intact leaf. For each, find the n per group (2-12) whose Student or Welch P is closest to the printed P, to show what the numbers imply. This is an inference. Superseded after the supplement arrived: the raw-count means in Tables S2 and S3 come in quarters and in sevenths or sixths, which fits 4 control readings against 7 and 6 coil readings (recheck_tables.py). This rule assumes equal groups, so its "5-6 per group" is kept below only as a record. 4. Changes in percent, from the printed means. 5. A tally of the comparisons the paper shows, counted by eye from its table and figures; the JIP-test table (S2) and Data Set S1 are in the supplement, which we have not got, so this is a floor. Updated after the supplement arrived; see the note above TALLY. Still our count. 6. Added after a fresh review of the page (RULES_review_addendum.txt, R2, R3), not before the first run. Fig. 3K has 8 asterisks, not 7, so the tally is one higher. Report the tally without Fig. 3H-K as well. And a post hoc reading of Table 1: Holm on total oil and carvone alone, the two outcomes the abstract names. Pure Python; run with `python3 -I`. Usage: python3 -I recheck_stats.py ======== THE LASCHAMP SURFACE FIELD: lsmod2_surface.py ======== How low, how widely and for how long did Earth's surface field fall at the Laschamp excursion? Our own evaluator of LSMOD.2 (Korte & Brown 2019, GFZ Data Services, CC BY 4.0), the preferred model of Korte et al. (2019). The file format and spline logic follow the site's earlier evaluator, verification/field-falters/code/report-C/lsmod2_dm.py; the authors' Fortran is not executed. RULES, fixed before the first run (2026-11-04): 1. Field: total intensity F from the internal Gauss coefficients at r = a = 6371.2 km, degree 10, on a sphere (no altitude, no oblateness). 2. Grid: 1-degree cell centres, weighted by cos(latitude). Time: every 10 years from 44.00 to 38.00 ka BP, the excursion's main span in Korte et al. (2019) section 4.4 and Table 2. 3. Per epoch: lowest F on the grid, refined on a 0.05-degree grid around the coarse minimum; area-weighted mean and median; area below 30 nT, 100 nT, 300 nT, 1 uT, 5 uT, 10 uT. 4. Per location: lowest F reached in the span, and the longest unbroken spell below 100 nT, 300 nT, 1 uT and 5 uT. Report the area that ever went below each level. 5. Validation: Korte et al. section 4.6 give a lowest surface value of 0.12 uT for their preferred model, and 3.7 ZAm2 as the model's lowest dipole moment (Table S5, as read for /field-falters/). If we do not reproduce those to within rounding, the numbers are not used. 6. A sanity check on the evaluator: a pure dipole must give |g10| at the equator, 2|g10| at a pole. 7. Reading the result: a model truncated at degree 10 and built from smoothed sediment records cannot resolve small-scale field, and a lowest value is where three components happen to pass near zero at a point. It is a rough guide to area and time, not a measurement at any place. Added after the first run, as description only (no new test): the summary of the main phase, the distribution over the surface at the lowest median, and the list of cells and decades below 30 nT. Outcome of rule 5: the dipole moment reproduces (3.67 ZAm2). Korte's 0.12 uT could not be matched to its digits: our lowest values per decade near 40.6 ka scatter from 29 to 910 nT, and Korte's epoch and grid are not stated. So point minima from this script are indicative only, and the page cites Korte for the point minimum. Added after a fresh review of the page (RULES_review_addendum.txt, R4), not before the first run: --fine also runs a yearly 1-degree grid and a 2-year 0.5-degree grid and writes lsmod2_sampling.json, because the two lowest rows of the area table depend on sampling. The first run's outputs do not change. Rule 5 was relaxed: Korte's 0.12 uT was not reproduced, yet the areas are used, because they do not rest on the point minimum; the page says so. Needs numpy; the script downloads LSMOD2.zip from GFZ Data Services (CC BY 4.0) unless you give it a local copy, checks its SHA-256, and reads the model file from inside it. The zip's Fortran is neither extracted nor run. --fine takes several minutes and over 1 GB of memory. Usage: py -3.12 -I lsmod2_surface.py [] [--fine] ======== THE COIL ESTIMATE: coil_uniformity.py ======== How far from the sensor does a coil-cancelled field stay near 30 nT? A geometry estimate. The mint paper reports one sensor "at the geometric center of the coil assembly" and ~30 nT. It refers to Agliassa et al. (2018) for the system: three orthogonal pairs of octagonal coils, X 128 cm across and 55 cm apart, Y (vertical) 150 and 67, Z 135 and 59, cancelling Bx = 6.39, By = 36.08, Bz = 20.40 uT. RULES, fixed before the first run (2026-11-04): 1. Ideal coils, thin wire, regular octagons, and a perfectly uniform ambient field. Real rooms are worse, so this is a lower bound on the residual, due to the coils' geometry alone. 2. "128 cm across" is ambiguous for an octagon, so run it twice: across corners and across flats. 3. Each pair's current is set so its field cancels that axis's ambient component exactly at the centre. 4. Report the residual |B| along each axis at 5-35 cm from the centre, the worst point on a sphere of each radius, and the share of a 50 x 50 x 50 cm and a 30 x 30 x 30 cm cube below 100 nT, 300 nT and 1 uT. 5. This says nothing on what the plants felt in fact. The paper does not give their positions, or how many shared the coil at once. At least 30 per treatment, in 500 mL flasks, would need a footprint of roughly 60 x 50 cm if they were in the coil together. 6. Added after a fresh review of the page (RULES_review_addendum.txt, R6), not before the first run: at least 4,000 directions on each sphere plus the six axis directions, because 60 directions missed the worst point; worst and median at each radius; and a run at twice the linear size, for the frame of about 2 m that the lab gives elsewhere (Bertea et al. 2015). Ambient and geometry are otherwise unchanged. The arithmetic now uses numpy, with the same element sums. Needs numpy. Run with `py -3.12 -I` on this machine. Usage: py -3.12 -I coil_uniformity.py ======== THE READINGS OFF FIGURES: figure_values.py ======== Values READ OFF the bars of Figures 1B, 2A-E, 3A-D and 5A-C of Mannino et al. (2026), by pixels. The paper gives most of these only in its supplement (Tables S2-S4, Data Set S1), which we had not got when this was written; its tables replaced these readings where they overlap. Every value here is a reading of the PDF's embedded raster image, good to about +/- 2 pixels; the "resolution" field gives what 1 pixel is worth in the axis's units. Geometry below comes from scanning pixel rows and columns for tick marks and bar edges. Outlined bars are read at the middle of the outline; a bar's error is the distance to the far edge of its error bar, less half the cap's thickness. Run with `python3 -I`. Usage: python3 -I figure_values.py