RULES_juliusruh_solar.txt - Test S: has NmF2's response to solar flux at Juliusruh weakened from SC20 to SC24? Written 2026-11-06 before the test was run. Shared definitions: RULES_common.txt. The claim re-run (Ann. Geophys. 2025, Sect. 3.2 and abstract): in January at 14 LT the cubic NmF2-F30 curves fall from cycle to cycle; SC24 lies below SC20 by "consistently higher than 0.29 % per year, reaching 0.44 % per year at 90 sfu" (2.9-4.4 % per decade). Data: Juliusruh foF2 hourly (downloads/sws-wdc-juliusruh/031800.YY.gz), F30 (Bremen), GFZ Kp. Cleaning, as the paper: drop NmF2 > 4e12 m^-3; drop every UT day whose largest Kp is >= 3.0, and the 48 h after it (the next two UT days). Main run: January, 13 UT (14 LT); all numeric foF2 values whatever their letters. Fit, per cycle SC20-SC24: least-squares cubic NmF2 = a0 + a1 X + a2 X^2 + a3 X^3, X = F30 (sfu). Outputs: the fitted NmF2 at F30 = 60, 70, 80, 90, 100, 110, 120 sfu, for each cycle whose observed F30 range covers that value (at least 5 points at or beyond it on each side within the cycle); the percentage difference SC24 - SC20, and that difference per year, dividing by the 43.6 years between the cycles' midpoints (SC20 1970.2, SC24 2013.8); also by 44.0 years (start to start). 95% bootstrap intervals for the SC24 - SC20 difference: resample days within each cycle, 2000 resamples, seed 20261106. Decision rule: the paper's direction is reproduced if SC24 - SC20 < 0 at every F30 value both cycles cover; its size is reproduced if the per-year decrease at 60 sfu is within a factor of 1.5 of 0.29 % and at 90 sfu within a factor 1.5 of 0.44 %. Sensitivity runs (each reported, none replaces the main run): S-a 14 UT instead of 13 UT; S-b values with qualifying letters D, E, I or U dropped; S-c days with Kp >= 2.0 also removed (the paper's own check); S-d F30 replaced by F10.7obs from the GFZ file. Instrument history (Ann. Geophys. 2025, Sect. 2.2): KOS ionosonde 1990-1994, digisonde from 1994, a single scaler from 1993. S-e SC22 refitted without 1990-1994. S-f a residual series: one cubic fit to all quiet January 13-UT data 1957-2025; the annual median residual (percent of the fit); report its linear trend 1964-2019 with a 95% interval, and the best single step (year of the step chosen by least squares among 1970-2014) with its size, and the residual sum of squares of both models. Descriptive only: it says whether the decline looks gradual or step-like; it decides nothing on its own.